Auto Stack Number Assignment
During the stack formation process, a unique
FTOS Version Checking
Following the
If the Master Switch determines that all switches are not running the same FTOS version, the ports on switches with the incorrect version are disabled.
To download the required FTOS image from the Master Switch and reload a member switch so that it joins the stack, enter the following command in EXEC Privilege mode:
FTOS# upgrade system
Where
FTOS# upgrade system
To display the boot partition used on the Master Switch, enter the show version command.
To ensure that a stack unit boots from partition a:, enter the commands:
FTOS# configure
FTOS(conf)# boot system
a:
FTOS(conf)# end
FTOS# write memory
FTOS#
NOTE: When an MXL 10/40GbE Switch is stacked, booting is supported only from flash memory; it is not supported over the network via an IP address.
NOTE: To upgrade all switches in a stack with the same FTOS version in a specified partition, enter the following command in EXEC Privilege mode:
FTOS# upgrade system {ftp: tftp:} partition
This command uses an interactive CLI that requests the server IP address and image filename, and prompts you to upgrade all member stack units. After
Assembling a Switch Stack
29