upgrading all switches in the stack, save the configuration (using the write memory command) and reload the stack to activate the new FTOS version (using the reload command).
System Initialization
The Master Switch initializes the stack using the last saved system configuration file.
If you change the stack configuration, be sure to save the configuration file. The Master Switch automatically distributes the configuration file to the member switches. If the Master Switch later becomes unavailable, the Standby Master becomes the new Master Switch and configures the stack with the latest configuration synchronized from the Master Switch.
In case of a split stack in which the Master Switch in one of the new stacks was previously a member switch, the last saved configuration on the original stack is used to configure the new stack.
Splitting 40GbE QSFP+ Ports into 10GbE SFP+ Ports
The MXL 10/40GbE Switch supports splitting a 40GbE port on the base module or a
NOTE: By default, the 40GbE ports on a
Before you attach a 4x10G breakout cable to a 40GbE QSFP+ port, ensure that the following requirements are met:
•A 4x10GbE QSFP+ port cannot be used for stacking.
•In order for a 40GbE port to operate in 4x10GbE mode, you must enter the
FTOS(conf)#
30
Splitting 40GbE QSFP+ Ports into 10GbE SFP+ Ports