CHAPTER 6: PREVENTATIVE MAINTENANCE

YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 6: PREVENTATIVE MAINTENANCE

Well-maintained equipment operates more efficiently and lasts longer. Keep the fryer clean during the day and thoroughly clean it at the end of each day.

6.1 Daily DANGER

Never attempt to clean the fryer during the cooking process or when the frypot is filled with hot oil. If water comes in contact with oil heated to cooking temperature, it will cause spattering of the oil, which can result in severe burns to nearby personnel.

6.1 Daily

Wash all removable parts. Clean all exterior surfaces. Do not use cleansers, steel wool, or any other abrasive material on stainless steel. Filter the oil and replace it if necessary. Filter oil more often under heavy use conditions (e.g., frying heavily breaded products).

6.2 Weekly WARNING

Use a commercial-grade cleaner formulated to effectively clean and sanitize food- contact surfaces. Read the directions for use and precautionary statements before use. Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food-contact surfaces.

Manual background WARNING

Water MUST NOT be allowed to drain into the filter pan or filter system. Irreversible damage will result if water is allowed into the system, and all applicable warranties will be voided.

6.2 Weekly

Completely drain the frypot into either the filter or a steel container. Do not use a plastic bucket or glass container.

Clean the frypot with a high grade cleaner or hot water and a strong detergent.

Close the drain valve and refill with either the cleaning solution or water and detergent.

Scrub frypot walls and heating tubes. Then drain frypot and rinse in clear water.

Once cleaning is completed, drain, rinse, and dry thoroughly.

Refill with shortening as directed in Section 3.10 of this manual.