Frymaster 8BC, 8SMS, 8C manual Operator Troubleshooting Guides Continued

Models: 8C 8BC 8SMS

1 54
Download 54 pages 35.64 Kb
Page 22
Image 22
Manual background

Operator Troubleshooting Guides (Continued)

WATER BOILS

IN SIMMER

MODE.

Adjust controller in

accordance with

procedure in Chapter 4.

Did boiling

stop?

No

Is a controller

known to be working

available?

No

Problem is beyond the scope of operator troubleshooting.

Call FASC.

YesManual background Problem resolved.

 

 

 

Substitute the controller

 

 

 

known to be working for

Yes

 

 

 

 

the suspect controller and

 

 

 

 

 

 

attempt to operate unit.

 

 

 

 

 

 

 

 

 

 

Did boiling

 

 

 

Problem is a failed controller.

 

Yes

 

Order replacement from FASC

stop?

 

 

 

 

 

or distributor.

 

 

 

 

 

 

 

No

Probable cause is a failed/ shorted temperature probe.

Call FASC.

5-5

Page 22
Image 22