Frymaster 8SMS, 8BC, 8C manual 480/120VAC DUAL VOLTAGE CONFIGURATION, L1 L2 L3, Load

Models: 8C 8BC 8SMS

1 54
Download 54 pages 35.64 Kb
Page 42
Image 42
L1 L2 L3

120VAC CORDSET

71C

11C

 

BLACK

 

IN-LINE

 

SPLICE

3 PHASE 3 WIRE

15C

FIELD CONNECTION

 

L1 L2 L3

WHITE

GRN

5AMP TYPE 3AG

FUSE

3C

71C

LOAD

24VAC 50 VA.

TRANSFORMER

5C

120 VAC

11CLINE

 

 

COM

 

16C

HIGH LIMIT

 

71C

 

 

8C

 

N.C. C

OPTIONAL AUTOFILL

CONNECTOR

71C

GEAR

MOTOR GM

BASKET LIFT SHOWN

IN UP POSITION

MICRO C

SWITCH

N.C. N.O.

1

3

5

7

9

11

IN-LINE SPLICE

 

 

 

 

 

 

2

4

6

8

10

12

 

 

1HV

 

2HV

3HV

 

1C1

 

1C2

1C3

 

1

2

5

3

4

6

6-17

24C

CONTACTOR

COIL1C 24 VAC

SOLENOID

24 VAC

 

 

 

11C

 

LOW

 

 

 

2

WATER

 

 

 

5

SENSOR

HIGH

COM

7

 

 

 

 

 

 

WATER

A B

 

 

 

 

 

SENSOR

24VDC

 

 

 

 

 

 

44C43C

NC

NO

BASKET LIFT RELAY

TEMP.

PROBE

1C

2C

4C

1 2 3 4 5

 

7C

 

9C

10C

 

12C

X

X

 

 

 

 

 

 

 

 

13C

14C

 

6

7

8

9

10

11

12

13

14

15

SOUND DEVICE

1

 

2

 

3

4

 

5

 

6

 

7

8

9

 

 

HOT

COM

NC

HEAT

 

NC

WATER

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

FILL

 

 

DO NOT MEASURE

 

 

 

POWER IN

 

 

 

 

 

 

 

 

 

WATER LEVEL PROBES

 

 

24VAC

GND.

 

NO VOLTAGE

 

 

GROUND WHEN

 

 

 

 

 

 

 

 

 

 

WHEN HEATING

 

FILLING 24VAC

 

 

 

 

 

 

 

 

 

 

 

24VAC WHEN

 

 

WHEN NOT

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

FILLING

 

 

 

 

 

 

COMPUTER CONTROL

ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING

8050462C

480/120VAC DUAL VOLTAGE CONFIGURATION

10

11

12

 

13

 

14

 

 

15

 

 

SD

 

 

 

TEMPERATURE

NC

 

 

3 TO 5

 

 

 

 

PROBE

 

 

 

 

 

VOLTS

 

 

 

 

 

 

 

 

 

 

 

WHEN SOUNDING

 

 

 

 

 

 

 

 

 

 

2 TO 3

 

NO VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTS DC

 

 

 

 

 

 

BASKET LIFT

 

 

DEPENDING

 

 

 

 

 

 

 

ON THE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 VOLTS WHEN

13 TO 17

WATER

 

 

 

 

TEMPERATURE

 

 

 

BASKET IS DOWN

VDC

 

 

 

 

 

 

 

 

 

13 TO 17 VDC

VRELAY

 

 

 

 

 

 

WHEN BASKET

 

 

 

 

 

 

 

 

 

IS UP

Page 42
Image 42
Frymaster 8SMS, 8BC, 8C manual 480/120VAC DUAL VOLTAGE CONFIGURATION, L1 L2 L3, Load