6.5 Wiring Diagrams

3 PHASE 3 WIRE

FIELD CONNECTION

 

 

 

L1

L2

L3

 

 

 

 

 

 

 

 

 

 

TYPE 5AMP 11C

 

 

 

 

 

17C 15C

 

16C

 

 

 

 

 

 

 

1HV

 

2HV

3HV

]

8C

 

 

1C1

 

1C2

1C3

TYPE 5AMP

 

 

 

 

1

2

 

5

3

4

6

 

 

 

3 PHASE 4 WIRE

 

 

 

 

 

FIELD CONNECTION

 

 

 

 

 

L1

L2

L3

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

8C

 

1HV

 

3HV

 

4 5

 

 

 

 

1C1

2HV

1C3

 

 

 

 

 

 

1C2

3

 

6

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

16C

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

11C

 

 

 

 

 

 

 

TYPE 5AMP

 

 

 

 

 

 

 

 

 

 

15C

 

 

6-

SINGLE PHASE

 

16

 

FIELD CONNECTION

 

L1

L2

L3

NEUTRAL TO L3

 

 

 

11C

3C

24V

 

TRANSFORMER

 

5C

 

COM

71C

16C

 

POSITION TAP

OPTIONAL

8C AS REQUIRED

HI LIMIT

AUTOFILL

SOLENOID

 

24 VAC

N.C. C

 

24C

LOW

 

WATER

 

SENSOR

1C

CONTACTOR

COIL

 

24 VAC

HIGH

WATER

SENSOR

OPTIONAL BASKET LIFT

71C

GEAR

MOTOR

BASKET LIFT

SHOWN IN

UP POSITION

N.C.COM.

N.O.

11C

44C

43C

 

2

NC

 

5NO

COM 7

BASKET LIFT RELAY

A B

24VDCTEMP.

PROBE

6.5 Wiring Diagrams

1HV

 

 

1C1

2HV

8C

1

1C2 3HV

4

1C

2C

4C

7C

9C

10C

12C

 

X

 

 

X

 

13C

14C

 

 

 

 

 

 

 

1C3

5

 

2

 

3

6

 

 

 

11C

 

 

16C

 

15C

TYPE 5AMP

SINGLE PHASE (NO NEUTRAL)

FIELD CONNECTION

1

1

2

2

3

3

4

4

5

6

7

8

9

10

11

5

6

7

8

9

10

11

1213

1213

14

14

15

15

SOUND DEVICE

 

 

L1

L2

L3

 

1HV

 

 

 

 

 

1C1

2HV

3HV

 

17C

8C

1

 

 

TYPE 5AMP

1C2

1C3

 

4

 

 

 

2

3

 

5

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

11C

 

 

 

 

 

16C

 

 

 

 

15C

TYPE 5AMP

HOT

COM

NC

HEAT

NC

WATER

NC

 

SD

 

 

 

TEMPERATURE

NC

POWER IN

 

 

 

FILL

 

 

3 TO 5 VOLTS

 

 

 

PROBE

 

 

 

24VAC

GND.

 

NO VOLTAGE

 

GROUND WHEN

DO NO MEASURE

 

WHEN SOUNDING

 

2 TO 3

NO VOLTAGE

 

 

WHEN HEATING

 

FILLING

WATER LEVEL PROBES

 

 

 

 

 

VOLTS DC

 

 

 

 

 

 

BASKET LIFT

 

 

 

 

 

 

 

 

 

24VAC WHEN OFF

 

24VAC WHEN

 

 

 

 

 

DEPENDING

 

 

 

 

 

 

 

 

NOT FILLING

 

 

 

 

 

 

ON THE

 

 

 

 

 

 

 

 

 

0 VOLTS WHEN

13 TO 17

 

 

 

 

 

 

 

 

 

 

WATER

 

 

 

 

 

 

 

 

 

 

BASKET IS DOWN

 

VDC

 

 

 

 

 

 

 

 

 

 

 

TEMP.

 

 

 

 

 

 

 

 

 

 

13 TO 17 VDC

 

RELAY

 

 

 

 

 

 

COMPUTER CONTROL

 

 

 

 

 

 

 

 

WHEN BASKET

 

 

 

 

 

 

 

 

 

 

IS UP

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDARD (SINGLE VOLTAGE) CONFIGURATION