NAVY SURFACE SHIP ELECTRIC FRYERS

NAVY SURFACE SHIP ELECTRIC FRYERS

CHAPTER 7: SERVICE PROCEDURES

7.1General

Before performing any maintenance on this equipment, disconnect the fryer from the electrical power supply.

When electrical wires are disconnected, it is recommended that they be marked in such a way as to facilitate re-assembly.

7.2Replacing a Controller

1.Remove the two screws from the upper corners of the control panel on fryers that have 90º angle topcaps. The controller bezel on fryers that have rounded topcaps is held in place by tabs at the top and bottom. Slide the bezel up to disengage the lower tabs. Then slide the bezel down to disengage the upper tabs. If applicable, remove the top two screws holding the controller to the control panel frame. The control panel is hinged at the bottom and will swing open from the top.

Remove screws in upper corners of control panel and swing panel down.

2.Unplug the wiring harness from the connector on the back of the controller and disconnect the grounding wire from terminal adjacent to the connector. Remove the control panel assembly by lifting it from the hinged slots in the control panel frame.

15-Pin Connector

Ground Wire Terminal

 

3.Remove the controller from the control panel assembly and install the replacement controller. Reinstall the control panel assembly by reversing steps 1 and 2.

7-1

Page 31
Image 31
Frymaster H22SC, H17SC, H14SC manual Navy Surface Ship Electric Fryers Service Procedures, General, Replacing a Controller