Frymaster H17SC, H22SC, H14SC manual Components Description of Operation

Models: H14SC H22SC H17SC

1 74
Download 74 pages 37.65 Kb
Page 45
Image 45

7.12Components Description of Operation

a)Drain solenoid – When the return valve is opened, a microswitch activates and supplies 24V to the pump relay and solenoids.

b)Vacuum release solenoid – When the return valve is closed, it de-energizes the 24V to the pump relay and solenoids releasing the vacuum.

c)Full vat oil return switch –When the return valve is open, the 24V circuit is closed and it activates the pump relay and drain solenoid.

d)Dual vat oil return switch – When the return valve is open, the 24V circuit is closed and it activates the pump relay and drain solenoid.

e)Optional waste oil pump switch – The drain valves and oil return valves are closed. When the oil waste discharge valve is opened, the 24V circuit is closed, it activates the pump relay and drain solenoid.

f)Safety interlock switch – The interlock switch is in series with the high-limit. It is actuated when the drain valve opens, which opens the latch circuit which drops out the 12V circuit on the interface board. This removes power from the latching contactor which opens and de-energizes the heating elements.

7-15

Page 45
Image 45
Frymaster H17SC, H22SC, H14SC manual Components Description of Operation