Frymaster H14SC, H17SC, H22SC manual Reinstall the drain tube assembly

Models: H14SC H22SC H17SC

1 74
Download 74 pages 37.65 Kb
Page 38
Image 38
22.Reinstall the drain tube assembly.

21.Reconnect the drain safety switch wiring to the switch(es) in accordance with the diagram below then reinstall the switch covers.

RIGHT

58C BLKDRAIN SAFETY SWITCH

57C RED

LEFT

DRAIN SAFETY SWITCH

55C BLK(DUAL-VAT ONLY)

56C RED

22.Reinstall the drain tube assembly.

23.Reinstall the tilt housing and back panels, top cap, and top connecting strip.

24.Reinstall controllers in the control panel frame and reconnect the wiring harnesses and ground wires.

25.Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply.

7.8Built-in Filtration System Service Procedures 7.8.1 Filtration System Problem Resolution

One of the most common causes of filtration problems is placing the filter paper on the bottom of the filter pan rather than over the filter screen.

Manual background CAUTION

Ensure that filter screen is in place prior to filter paper placement and filter pump operation. Improper screen placement is the primary cause of filtration system malfunction.

Whenever the complaint is “the pump is running, but no oil is being filtered,” check the installation of the filter paper, and ensure that the correct size is being used. While you are checking the filter paper, verify that the O-ring on the bottom of the filter pan is present and in good condition. A missing or worn O-ring allows the pump to take in air and decreases its efficiency. Also, oil leaks on the floor each time a vat is drained.

If the pump motor overheats, the thermal overload will trip and the motor will not start until it is reset. If the pump motor does not start, press the red reset switch (button) located on the rear of the motor.

If the pump starts after resetting the thermal overload switch, then something is causing the motor to overheat. A major cause of overheating is when several frypots are filtered sequentially, thus overheating the pump and motor. Allow the pump motor to cool at least 30 minutes before resuming operation. Pump overheating can be caused by:

7-8