Frymaster H17SC, H22SC, H14SC manual Problem, Corrective Action, Probable Causes

Models: H14SC H22SC H17SC

1 74
Download 74 pages 37.65 Kb
Page 27
Image 27
Probable Causes

Problem

Probable Causes

Fryer repeatedly

cycles on and off Fryer is in melt-cycle mode. when first started.

Fryer does not heat

Drain valve is open.

after filtering.

 

Fryer heats until

Temperature probe or controller has

high limit trips with

failed.

heat indicator ON.

 

Fryer heats until

 

high limit trips

Contactor or controller has failed.

without heat

 

indicator ON.

 

Fryer stops heating

The high limit thermostat or

with heat indicator

contactor has failed.

ON.

 

Corrective Action

This is normal. The standard operational mode for the controller is for the elements to cycle on and off until the temperature in the frypot reaches 180ºF (82ºC). The purpose of the melt-cycle is to allow controlled melting of solid shortening to prevent scorching and flash fires or damage to the element.

This fryer is equipped with a drain safety switch that prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed.

If available, substitute a controller known to be working for the suspect controller. If the substitute controller functions correctly, order a new controller. If substitution of the controller does not resolve the problem, the most likely cause is a failed temperature probe.

If available, substitute a controller known to be working for the suspect controller. If the substitute controller functions correctly, order a new controller. If substitution of the controller does not resolve the problem, the most likely cause is a contactor failed in the closed position.

The fact that the heat indicator is ON indicates that the controller is functioning properly and is calling for heat. The high limit thermostat functions as a normally closed switch. If the thermostat fails, the "switch" opens and power to the elements is shut off. If the contactor fails to close, no power is supplied to the elements. Determining which component has failed is beyond the scope of operator troubleshooting. Call FASC.

6-3

Page 27
Image 27
Frymaster H17SC, H22SC, H14SC manual Problem, Corrective Action, Probable Causes