●Do not connect the contacts in series.

All installation and service on FRYMASTER equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel.

Service may be obtained by contacting a local Frymaster DEAN Factory Authorized Service Center.

In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored.

A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.

Connections should be made by means of an approved, flexible-metallic or rubber-covered electrical cable and quick-disconnect plug. The fryers may be installed with “hard-wired” connections, but use of quick-disconnect plugs will facilitate service if required. Connections are made to the fryer power input terminal block located in the contactor box(es) in the bottom of the fryer(s).

●Do not connect more than one fryer to each set of contacts. DANGER

Observe the following precautions when connecting the fryer to an emergency cutoff system:

Be sure that each fryer is connected to a dedicated set of contacts in the emergency cutoff system.

Do not connect the contacts in series.

Do not connect more than one fryer to each set of contacts.

The contacts MUST be normally closed contacts that open in an emergency.

The contacts CANNOT have an external voltage applied.

2.2Power Requirements

 

 

 

WIRE

MIN.

AWG

 

AMPS PER LEG

 

MODEL

VOLTAGE

PHASE

SERVICE

SIZE

(mm2)

 

 

 

 

 

L1

 

L2

 

L3

H14SC

440

3

3

8

(10)

19

 

19

 

19

H14SC

480

3

3

8

(10)

17

 

17

 

17

H17SC/FPH17SC

440

3

3

6

(16)

23

 

23

 

23

H17SC/FPH17SC

480

3

3

6

(16)

21

 

21

 

21

H22SC

440

3

3

6

(16)

29

 

29

 

29

H22SC

480

3

3

6

(16)

27

 

27

 

27

The FPH17SC Navy Surface Ship electric fryers are equipped with a filter system that requires a separate 120VAC, single-phase, 3-wire, 20 amp service (refer to wiring diagrams in paragraphs 7.10 and 7.11).

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

●The contacts CANNOT have an external voltage applied. DANGER

This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.

2-2

Page 8
Image 8
Frymaster H14SC Do not connect the contacts in series, Do not connect more than one fryer to each set of contacts, Danger