5.Turn the fryer ON/OFF switch(s) to the OFF position.

5.Turn the fryer ON/OFF switch(s) to the OFF position.

6.Add two gallons of water. Drain out the solution and clean the frypot(s) thoroughly.

5.1.4 Clean Detachable Parts and Accessories – Weekly WARNING

Do not drain boil-out solution into a shortening disposal unit, a built-in filtration unit, or a portable filter unit. These units are not intended for this purpose, and will be damaged by the solution.

7.Refill the frypot(s) with clean water. Rinse the frypot(s) twice, drain and dry with a clean towel. Thoroughly remove all water from the frypot and elements before refilling the frypot with cooking oil.

5.2Check Calibration of Temperature Control Knob – Monthly DANGER

Remove all drops of water from the frypot before filling with cooking oil. Failure to do so will cause spattering of hot liquid when the oil is heated to cooking temperature.

5.1.4 Clean Detachable Parts and Accessories – Weekly

Wipe all detachable parts and accessories with a clean, dry cloth. Use a clean cloth saturated with detergent to remove accumulated carbonized oil on detachable parts and accessories. Rinse the parts and accessories thoroughly with clean water and wipe dry before reinstalling.

5.2Check Calibration of Temperature Control Knob – Monthly

1.After the cooking oil reaches operating temperature, let the heating elements cycle at least four times (indicated by the HEAT light going out and coming back on).

2.Insert a thermometer or pyrometer probe near the temperature-sensing probe approximately five inches deep into the cooking oil. When the heating elements cycle on for the fourth time, the thermometer should read within ±5°F of the temperature control knob setting.

3.If the knob requires adjustment:

a.Loosen the setscrew in the control knob until the outer shell of the knob will rotate on the insert inside the knob.

b.Rotate the outer shell of the knob until the index line on the knob aligns with the mark that corresponds to the thermometer or pyrometer reading.

c.Hold the knob and tighten the setscrew.

d.Recheck the thermometer or pyrometer reading and the temperature control knob setting the next time the HEAT light illuminates.

e.Repeat steps a through d until the thermometer or pyrometer reading and the knob setting agree within 5°F.

5-3

Page 22
Image 22