Fujitsu B120 manual Connecting the rack server to the line voltage, Installation, V - 125, V - 240

Models: B120

1 68
Download 68 pages 12.34 Kb
Page 27
Image 27
3.5.3 Connecting the rack server to the line voltage

Installing rack-server in/removing from rack

Installation

1

2

Place the server on the slide rails in the rack (1) and secure the server with the four knurled screws in the rack (2).

3.5.3 Connecting the rack server to the line voltage

The server is equipped with a permanently installed standard power supply. Two standard designs are available for the power supply. The only difference between them is that the connection panel is rotated 180°. Since the connection panels are otherwise identical, the diagrams below show only one of the standard power supplies.

The power supply of the server can be set to the following line voltage range: 100 V to 125 V or 200 V to 240 V.

Before connecting the server to the line voltage, you must always check that the line

! voltage range set on the server corresponds to the local line voltage. The marker arrow on the plug-in unit points to the voltage range set.

100 V - 125 V

a

200 V - 240 V

ÊIf the wrong line voltage is set, lift out the plug-in unit with a screwdriver (a), turn it and replace it.

A26361-K646-Z102-1-7619

19

Page 27