Setting up the tower server

Installation

3.4.1 Connecting the tower server to the line voltage

The server is equipped with a permanently installed standard power supply.

Two standard designs are available for the power supply. The only difference between them is that the connection panel is rotated 180°. Since the connection panels are otherwise identical, the diagrams below show only one of the standard power supplies.

Both designs for the standard power supply can be set for supply voltage ranges 100 V to 125 V or 200 V to 240 V.

Before connecting the server to the line voltage, you must always check that the line

! voltage range set on the server corresponds to the local line voltage. The marker arrow on the plug-in unit points to the voltage range set.

100 V - 125 V

200 V - 240 V

a

 

ÊIf the wrong line voltage range is set, lift out the plug-in unit with a screwdriver (a), turn it and replace it.

2

1

ÊConnect the power cable to the server's power connector (1) and to a free grounded power outlet (2).

A26361-K646-Z102-1-7619

13

Page 21
Image 21
Fujitsu B120 manual Connecting the tower server to the line voltage, 125 240