LCD | Descriptions | Selectable | Default | Mode | Remarks | |
display |
| parameters |
|
|
|
|
|
| On- | Off- |
| ||
|
|
|
|
| ||
|
|
|
| line | line |
|
|
|
|
|
|
|
|
Abrasion | Specifies the scanners | Stop/Message | Stop | Avail- | Avail- | The |
Alarm | operation when consumables | 10,000 to | 300,000 | able | able | replacement |
| replacement occurs: stop | 2,560,000 sheets |
|
|
| timing |
| scanning or message display |
|
|
| increment/ | |
|
|
|
|
| ||
| only. Also specifies the |
|
|
|
| decrement by |
| consumable replacement |
|
|
|
| 10,000 sheets. |
| message timing. |
|
|
|
|
|
|
|
|
|
|
|
|
Abrasion | Clear the consumable counters | - | - | Not | Avail- | - |
Counter | (Abrasion counter) |
|
| Avail- | able |
|
|
|
|
| able |
|
|
|
|
|
|
|
|
|
Manual Feed | Specifies the pick start time | 0.2 to 29.8 sec | 1.0 sec | Avail- | Avail- | - |
| from the time document is |
|
| able | able |
|
| manually set. |
|
|
|
|
|
|
|
|
|
|
|
|
| Specifies the waiting time from | 1, 5, 10, 20, 30, | 30 sec |
|
|
|
| the execution of read command | 40, 50, 60, 70, 80, |
|
|
|
|
| on PC to document insertion. | 90, 100, 110, 120, |
|
|
|
|
|
| 180, 240, 255 sec |
|
|
|
|
|
|
|
|
|
|
|
7