The available ranges of detection are as follows:

Top: 0 (default), 50, 100, 150, 200 (Unit : mm)

L: 100 (default), 150, 200 (Unit : mm)

5)Besides the Double-feed detection by checking paper overlapping (the amount of ultrasonic waves), you can enable or disable the detection by checking paper thickness (the amount of light) at <Screen 4-3>. Press (Left arrow button) or

(Right arrow button) to enable or disable the detection by checking paper thickness.

<Screen 4-3>

! 0 4 - 3

+

T h i

c

k n e s s

N

o

/ Y e

s

 

(1)

[Yes] is blinking:

The Double-feed deteciton by checking

 

 

paper thickness is executed.

(2)

[No] is blinking:

The Double-feed deteciton by checking

 

 

paper thickness is not executed.

Press

(Enter button) to enable the setting.

6)When the LCD is showing (2) or (3), pressing (Enter button) changes LCD display to <Screen 4-4>.

<Screen4-4>

! 0 4 - 4

D

F

M o

d e

=

T h

i

c k

n e

s s

7)At <Screen4-4>, by pressing (Left arrow button) or (Right arrow button), you can select the detection mode.

Each time (Left arrow button) or (Right arrow button) is pressed, LCD displays [Thickness] and [Thickness & Roller] alternately.

<Screen4-4>

7

MENUS PANEL OPERATOR

7.3 Setup Mode Details 7-23