LCD | Descriptions | Selectable | Default | Mode | Remarks | |
display |
| parameters |
|
|
|
|
|
| On- | Off- |
| ||
|
|
|
|
| ||
|
|
|
| line | line |
|
|
|
|
|
|
|
|
Baud Rate | Specifies the control data | 19200 / | 9600 | Not | Avail- | New setting |
| transfer rate for TPS interface. | 9600 / |
| Avail- | able | valid after |
|
| 4800 / |
| able |
| power cycle. |
|
|
|
|
|
| |
|
| 2400 |
|
|
|
|
|
|
|
|
|
|
|
Imprinter | When both | Pre / Post | - | Avail- | Avail- | - |
|
|
| able | able |
| |
| 486PRRE (Rear side/Post- |
|
|
|
|
|
| print) are installed, specifies |
|
|
|
|
|
| which one to setup. |
|
|
|
|
|
|
|
|
|
|
|
|
Numbering | When either | Numbering | Numberin | Avail- | Avail- | Settings via the |
| (Front | : On / Off | g | able | able | PC have the |
| 486PRRE (Rear side/Post- |
| : Off |
|
| priority. |
| print) is installed, set the |
|
|
|
|
|
| Digits | Digits |
|
|
| |
| numbering parameters. |
|
|
| ||
|
| : 5 / 8 | : 5 |
|
|
|
|
|
|
|
|
|
|
|
| Initial No.: | Initial No.: |
|
|
|
|
| 00000 |
|
|
| |
|
| 8digit: |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Reset at hopper | Reset at |
|
|
|
|
| empty: On/Off | hopper |
|
|
|
|
|
| empty: On |
|
|
|
|
|
|
|
|
|
|
Ink | Shows the remaining ink. | - | - | Avail- | Avail- | - |
| Reset remaining ink amount |
|
| able | able |
|
| counter when the Print |
|
|
|
|
|
| cartridge is replaced. |
|
|
|
|
|
|
|
|
|
|
|
|
7
MENUS PANEL OPERATOR