Hardware Installation and Service Issues
This section describes hardware specific issues and workarounds.
Specific Issues and Workarounds
TABLE 1 lists known hardware issues and possible workarounds.
TABLE 1 Hardware Issues and Workarounds
CR ID | Description | Workaround |
|
|
|
6433420 The domain console might display a Mailbox timeout or IOCB interrupt timeout error during boot.
6488846 During boot, the domain console might display a checksum error for the SG(X)PCI2SCSIU320- Z SCSI controller I/O card.
6557379 Power cables are not redundant on single power feed servers without the dual power feed option.
Issue a reset
Check for the availability of the latest controller card firmware.
On servers that have single power feed, all power cables must be connected and powered on at all times.
6 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 • November 2007