TABLE 4 Specific Issues and Workarounds Concerning Solaris (Continued)

CR ID

Description

Workaround

 

 

 

6564934 Performing a DR deleteboard(8) operation on a board which includes Permanent Memory when using the following network cards results in broken connections:

X4447A-Z, PCI-e Quad-port Gigabit Ethernet Adapter UTP

X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter

6568417 After a successful CPU DR deleteboard(8) operation, the system panics when the following network interfaces are in use:

X4447A-Z, PCI-e Quad-port Gigabit Ethernet Adapter UTP

X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter

6571370 Use of the following cards have been observed to cause data corruption in stress test under laboratory conditions:

X4447A-Z, PCI-e Quad-port Gigabit Ethernet Adapter UTP

X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter

6572827 On SPARC Enterprise M8000/M9000 servers, one of the columns in the IO Devices section of the output from prtdiag -vis "Type". This reports "PCIe", "PCIx", "PCI" or "UNKN" for each device.

The algorithm used to compute this value is incorrect. It reports "PCI" for PCI-X leaf devices and "UNKN" for legacy PCI devices.

6584984 On SPARC Enterprise M8000/M9000 servers, busstat(1M) command may cause rebooting of domains.

6588650 On occasion, the system is unable to DR after an XSCF failover or XSCF reboot.

Re-configure the affected network interfaces after the completion of the DR operation. For basic network configuration procedures, refer to the ifconfig man page for more information.

Check for the patch 127741-01 for this detect.

Add the following line to /etc/system and reboot the system:

set ip:ip_soft_rings_cnt=0

Check for the patch 127111-02 for this detect.

Add the following line in /etc/system and reboot the system: set

nxge:nxge_rx_threshold_hi=0

For Solaris 10 8/07, check for the patch 127741- 01 for this defect.

For Solaris 10 11/06, check for the patch 125670-04 for this defect.

There is no workaround.

None available at this time. Do not use busstat(1M) command.

Check for the availability of a patch for this defect.

There is no workaround. Check for the availability of a patch for this defect.

SPARC Enterprise M8000/M9000 Servers Product Notes 23