13.Wait until XSCF firmware reaches the ready state.

This can be confirmed when the READY LEDs of XSCF_B#0 and XSCF_B#1 remain lit.

14.Log in on to XSCFU#0 using a serial connection or LAN connection.

15.Confirm no abnormality occurred by using showlogs error -vand showstatus(8) commands.

XSCF> showlogs error -v

XSCF> showstatus

If you encounter any hardware abnormality of the XSCF contact your authorized service representative.

16.Confirm and update the imported XCP image again.

XSCF> flashupdate -c update -m xcp -s version

Specify the XCP version to be updated. In this example, it is 1060. XSCF#1 will be updated, and then XSCF#0 updated, again.

When the firmware update for XSCF#0 is complete, XSCF#1 is active.

17.Log in to XSCFU#1 using a serial connection or LAN connection.

18.Confirm completion of the update by using the showlogs event command.

XSCF> showlogs event

Confirm no abnormality is found during the update.

28 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 • November 2007