6.Collect an XSCF snapshot to archive system status prior to upgrade.
XSCF> snapshot
7.The BUI on XSCFU#0 can be used to upload the XCP 1060 upgrade image.
8.Update the firmware by using the flashupdate(8) command.
Caution – flashupdate(8) will update one bank, reset the XSCF and commence update of the second bank. Verify that the current and reserve banks are both updated. If both banks indicate XCP revision 1060, proceed to the next step.
XSCF> flashupdate
Specify the XCP version to be updated. In this examples, it's 1060.
9.Confirm completion of the update.
XSCF> showlogs event
Confirm no abnormality happens while updating XCSF_B#0.
10.Confirm that both the current and reserve banks of XSCFU#0 display the updated XCP versions.
XSCF> version
XSCF#0 (Active)
XCP0 (Reserve): 1060
XCP1 (Current): 1060
XSCF#1 (Standby)
XCP0 (Reserve): 0000
XCP1 (Current): 0000
If the Current and Reserve banks on XSCF#0 do not indicate XCP revision 1060, contact your authorized service representative.
11.Turn off all of the server's mainline switches for 30 seconds.
12.After 30 seconds, turn the mainline switches back on.
SPARC Enterprise M8000/M9000 Servers Product Notes 27