TABLE 4

Specific Issues and Workarounds Concerning Solaris (Continued)

 

 

 

 

CR ID

Description

 

Workaround

 

 

 

6511374

Unexpected error messages may be displayed

This message can be safely ignored.

 

on console after changing the system

 

 

configuration.

 

 

 

Example:

 

 

 

WARNING: Translation error

source

 

 

/LSB0/B0/0, PA 3c000000000,

target

 

 

/LSB0/B0/20000000

 

 

6515648

"Replumb Failed" error appears when

Once the DR operation is complete, it can be

 

dr@0:SB1::memory fails.

 

plumbed up manually.

 

 

 

Example steps to re-plumb the interface

 

 

 

manually:

# ifconfig interface plumb xxx.xxx.xxx.xxx netmask + broadcast + up

# ifconfig interface group group-name

6516135 Ap_Id format and devices may not be shown correctly by cfgadm(1M).

6519290 Large amounts of I/O on swap devices can cause the system to appear hung by over welling the I/O system. The amount of I/O required can be generated through a number of ways, eg memory shortage, heavy use of /tmp etc.

6520990 Domain may cause a panic when deleteboard(8) command for kernel board by using Dynamic Reconfiguration (DR).

#ifconfig interface addif xxx.xxx.xxx.xxx

-failover deprecated up

This workaround assumes that the /etc/hostname.interface file is correctly configured for the IPMP group and does not need any modification. The IP addresses used in the example above should match what was previously used and what matches the /etc/hostname.<interface> file.

Use the following operations to display all of the PCI slots.

1)devfsadm (at Solaris prompt)

2)cfgadm

Set the following to /etc/system and then reboot the domain:

set maxfastscan=0x2000

To mask this error, add the following entry to the /etc/system file.

set drmach:fmem_timeout = 30

This bug has been fixed in Solaris 10 8/07.

18 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 • November 2007