TABLE 4

Specific Issues and Workarounds Concerning Solaris (Continued)

 

 

 

CR ID

Description

Workaround

 

 

 

6589546

prtdiag(8) command does not show all I/O

Use prtdiag -vfor full output.

 

devices of the following cards:

 

 

SG-XPCIE2FC-EM4 Sun StorageTek

 

 

Enterprise Class 4Gb Dual-Port Fibre

 

 

Channel PCI-E HBA

 

 

SG-XPCIE1FC-EM4 Sun StorageTek

 

 

Enterprise Class 4Gb Single-Port Fibre

 

 

Channel PCI-E HBA

 

6589644

After added the system board by DR, when the

The console can be recovered by pressing

 

switching occurred on the redundant XSCF

Ctrl-q(the "Ctrl" key and the "q" key).

 

Units, the domain console may hang up.

 

6589833 The DR addboard(8) command might cause a system hang if you are adding a Sun StorageTek Enterprise Class 4Gb Dual-Port Fibre Channel PCI-E HBA card (SGXPCIE2FC- QF4) at the same time that an SAP process is attempting to access storage devices attached to this card. The chance of a system hang is increased if the following cards are used for heavy network traffic:

X4447A-Z, PCI-e Quad-port Gigabit Ethernet Adapter UTP

X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter

6592302 Unsuccessful DR operation leaves memory partially configured.

6600730 Extra characters appear in a boot message string.

There is no workaround. Check for the availability of a patch for this defect.

Try deleteboard(8) again.

The extraneous characters can be safely ignored.

24 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 • November 2007