19.Confirm that both the current and reserve banks of XSCFU#1 display the updated XCP versions.

XSCF> version -c xcp

XSCF#1 (Active)

XCP0 (Reserve): 1060

XCP1 (Current): 1060

XSCF#0 (Standby)

XCP0 (Reserve): 1060

XCP1 (Current): 1060

If the Current and Reserve banks on XSCF#1 do not indicate XCP revision 1060, contact your authorized service representative.

Note – Setup RCI network if RCI is used. To setup RCI network, please consult your service provider.

20. Confirm switching over between XSCFs works properly.

XSCF> switchscf -t Standby

The XSCF unit switch between the Active and Standby states. Continue? [yn] :y

a.When the READY LED on XSCFU_B#1 and the ACTIVE LED on XSCFU_B#0 remain lit, log in to XSCFU#0 using a serial connection or LAN connection.

SPARC Enterprise M8000/M9000 Servers Product Notes 29