5.3 Host Commands
C141-E057-01EN 5-33
Table 5.4 Information to be read by IDENTIFY DEVICE command (2 of 7)
Word Value
Description
23-26
Firmware revision (ASCII code, 8 characters, left)
27-46
Set by a device
Model name (ASCII code, 40 characters, left)
47 X’8010’
Maximum number of sectors per interrupt on
READ/WRITE MULTIPLE command
48 X’0000’
Reserved
49 X’0B00’
Capabilities *3
50 X’0000’
Reserved
51 X’0200’
PIO data transfer mode *4
52 X’0000’
Reserved
53 X’0007’
Enable/disable setting of words 54-58 and 64-70, 88 *5
54
(Variable)
Number of current Cylinders
55
(Variable)
Number of current Head
56
(Variable)
Number of current sectors per track
57-58
(Variable)
Total number of current sectors
59 *6
Transfer sector count currently set by READ/WRITE
MULTIPLE command *6
60-61
*2
Total number of user addressable sectors (LBA mode only)
*2
62 X’0000’
Reserved
63
X’xx07’
Multiword DMA transfer mode *7
64 X’0003’
Advance PIO transfer mode support status *8
65 X’0078’
Minimum multiword DMA transfer cycle time per word :
120 [ns]
66 X’0078’
Manufacturer’s recommended DMA transfer cycle time :
120 [ns]
67 X’00F0’
Minimum PIO transfer cycle time without IORDY flow
control : 240 [ns]
68 X’0078’
Minimum PIO transfer cycle time with IORDY flow control
: 120 [ns]
69-79
X’0000’
Reserved
80 X’001E’
Major version number *9
81 X’0000’
Minor version number (not reported)
82 X’346B’
Support of command sets *10