3.3 Cable Connections

3.3.2 Cable connector specifications

Table 3.2 lists the recommended specifications for the cable connectors.

Table 3.2 Cable connector specifications

 

Name

Model

Manufacturer

 

 

 

 

ATA interface and power

Cable socket

89361-144

BERG

supply cable (44-pin type)

(44-pin type)

 

 

 

 

 

 

For the host interface cable, use a ribbon cable. A twisted cable or a cable with wires that have become separated from the ribbon may cause crosstalk between signal lines. This is because the interface is designed for ribbon cables and not for cables carrying differential signals.

3.3.3 Device connection

Figure 3.7 shows how to connect the devices.

Figure 3.7 Cable connections

C141-E057-01EN

3-9

Page 48