Interface

Bit 7:

If this bit is 1, it indicates that the automatic off-line data

 

collection function is enabled.

 

 

 

Status Byte

 

Meaning

 

 

 

0

 

Off-line data collection is not started.

 

 

 

2

 

Off-line data collection has been completed normally.

 

 

 

3

 

Off-line data collection is in progress.

 

 

 

4

 

Off-line data collection has been suspended by a command

 

 

interrupt.

 

 

 

5

 

Off-line data collection has been aborted by a command

 

 

interrupt.

 

 

 

6

 

Off-line data collection has been aborted by a fatal error.

 

 

 

Number of off-line data collection segments

Indicates the number of segments required to terminate off-line data collection.

Time required for next segment [sec]

Indicates the time required to terminate the next segment.

Current segment pointer

Indicates the number of the next segment to be executed.

Off-line data collection capability

Indicates the method of off-line data collection carried out by the drive. If the off-line data collection capability is 0, it indicates that off-line data collection is not supported.

Bit

Meaning

0Indicates that Execute Off-Line Immediate is supported.

1Vendor unique

2Indicates that off-line data collection being executed is aborted when a new command is received.

Failure prediction capability flag

Bit 0: The attribute value data is saved to a media before the device enters power saving mode.

Bit 1: The device automatically saves the attribute value data to a media after the previously set operation.

Bits 2 to 15: Reserved bits

5-62

C141-E057-01EN

Page 137