Operations

6.1.4 Response to diagnostic command

When the master device receives an EXECUTE DEVICE DIAGNOSTIC command and the slave device is present, the master device checks the PDIAG- signal for up to 6 seconds to see if the slave device has completed the self- diagnosis successfully.

The master device does not check the DASP- signal.

After the slave device receives the EXECUTE DEVICE DIAGNOSTIC command, it shall report the result of the self-diagnostics to the master device as described below:

PDIAG- signal: negated within 1 ms and asserted within 5 seconds

When the IDD is set to a slave device, the IDD asserts the DASP- signal when negating the PDIAG- signal, and negates the DASP- signal when asserting the PDIAG- signal.

Ifthe slavedeviceispreset,PDIAG- is checked for up to 6 seconds.

Figure 6.4 Response to diagnostic command

6-6

C141-E057-01EN

Page 193
Image 193
Fujitsu MHE2043AT, MHF2043AT, MHF2021AT, MHE2064AT manual Response to diagnostic command