Installation Conditions

3.4.4 CSEL setting

Figure 3.12 shows the cable select (CSEL) setting.

Open

1

 

C

 

A

 

 

 

 

2 D B Short

Note:

The CSEL setting is not depended on setting between pins Band D.

Figure 3.12 CSEL setting

Figure 3.13 and 3.14 show examples of cable selection using unique interface cables.

By connecting the CSEL of the master device to the CSEL Line (conducer) of the cable and connecting it to ground further, the CSEL is set to low level. The device is identified as a master device. At this time, the CSEL of the slave device does not have a conductor. Thus, since the slave device is not connected to the CSEL conductor, the CSEL is set to high level. The device is identified as a slave device.

Figure 3.13 Example (1) of Cable Select

3-12

C141-E057-02EN

Page 51
Image 51
Fujitsu MHE2064AT, MHF2043AT, MHE2043AT, MHF2021AT manual Csel setting