| 5.3 Host Commands | |
|
| Table 5.20 Data format of SMART Comprehensive Error Log | |||
|
|
|
|
|
|
| Byte |
| First sector | Next sector |
|
|
|
|
|
|
|
| 00 |
| SMART Error Logging 01h | Reserved |
|
|
|
|
|
|
|
| 01 |
| Index Pointer Latest Error Data Structure | Reserved |
|
|
|
|
|
|
|
| 02…5B |
| 1st Error Log Data Structure | Error Log Data Structure 5n+1 |
|
|
|
|
|
|
|
| 5C…B5 |
| 2nd Error Log Data Structure2 | Error Log Data Structure 5n+2 |
|
|
|
|
|
|
|
| B6…10F |
| 3rd Error Log Data Structure3 | Error Log Data Structure 5n+3 |
|
|
|
|
|
|
|
| 110…169 |
| 4th Error Log Data Structure4 | Error Log Data Structure 5n+4 |
|
|
|
|
|
|
|
| 16A…1C3 |
| 5thError Log Data Structure5 | Error Log Data Structure 5n+5 |
|
|
|
|
|
|
|
| 1C4…1C5 |
| Total number of drive errors | Reserved |
|
|
|
|
|
|
|
| 1C6…1FE |
| Reserved | Reserved |
|
|
|
|
|
|
|
| 1FF |
| Check sum | Check sum |
|
|
|
|
|
| |
| “n” indicates sector number in the Error Log. The first sector is 0. |
| |||
|
|
|
|
|
|
•SMART Self-Test
The host computer can issue the SMART Execute
The host computer can issue the SMART Read Log Sector