5.3 Host Commands

Table 5.25 Information to be read by IDENTIFY DEVICE command (2/3)

Word

Value

Description

 

 

 

 

65

X’0078’

Minimum multiword DMA transfer cycle time per word: 120 [ns]

 

 

 

66

X’0078’

Manufacturer’s recommended DMA transfer cycle time: 120 [ns]

 

 

 

67

X’00F0’

Minimum PIO transfer cycle time without IORDY flow control: 240 [ns]

 

 

 

68

X’0078’

Minimum PIO transfer cycle time with IORDY flow control: 120 [ns]

 

 

 

 

69-74

X’0000’

Reserved

 

 

 

 

 

75

X ' 001F '

Queue depth

*11

 

 

 

 

76

X ' 0702 '

Serial ATA capabilities

*12

 

 

 

 

77

X ' 0000 '

Reserved for Serial ATA

 

 

 

 

 

78

X ' 004C '

Support of Serial ATA function

*13

 

 

 

 

79

X ' 00xx '

Valid of Serial ATA function

*14

 

 

 

 

80

X’00F8’

Major version number

*11

 

 

 

 

81

X’001A’

Minor version number

 

 

 

 

 

82

X’346B’

Support of command sets

*12

 

 

 

 

83

X’7F09’

Support of command sets

*13

 

 

 

 

84

X’60xx’

Support of command sets/function

*14

 

 

 

 

85

*15

Valid of command sets/function

*15

 

 

 

 

86

*16

Valid of command sets/function

*16

 

 

 

 

87

*17

Default of command sets/function

*17

 

 

 

 

88

X’xx3F’

Ultra DMA transfer mode

*18

 

 

 

 

89

Set by a device

Security Erase Unit execution time (1 LSB: 2 min.)

*19

 

 

 

90

X’0000’

Enhanced Security Erase Unit execution time (1 LSB: 2 min.)

 

 

 

 

91

(Variable)

Advance power management level

 

 

 

 

 

92

(Variable)

Master password revision

 

 

 

 

 

93

X’0000’

COMRESET Result

 

 

 

 

 

94

(Variable)

Acoustic Management level

*21

 

 

 

 

95-99

X’0000’

Reserved

 

 

 

 

100-103

X’xx’

Total number of sectors accessible by users in the 48-bit LBA mode

 

 

 

*22

 

 

 

 

104-105

X’00’

Reserved

 

 

 

 

 

106

*26

Physical sector size per logical sector

 

 

 

 

 

107-116

X ' 0000 '

Reserved

 

 

 

 

 

C141-E224

5-91

Page 167
Image 167