Interface

Table 5.1

Physical Layer Electrical Requirements (2/3)

 

b) Transmitter Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units

Nom

Min

Max

 

Comments

 

 

 

 

 

 

 

 

ZdiffTX,

 

Ohm

 

85

115

 

 

TX Pair Differential

 

 

 

 

Impedance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zs-eTX,

 

Ohm

 

40

 

 

 

TX Single-Ended

 

 

 

 

 

Impedance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

c) Transmitted Signal Requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units

Nom

Min

Max

 

Comments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Differential

 

 

 

 

 

 

 

nominal measured

VdiffTX,

 

 

 

 

 

 

at Serial ATA

 

mVppd

500

400

600

 

connector on

TX Differential

 

 

transmit side

Output Voltage

 

 

 

 

 

 

 

 

 

 

 

 

(+/-250mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

differential@seria

 

 

 

 

 

 

 

l ATA connector)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rise: 20%-80% at

t20-80TX,

 

ps

 

0.15

0.41

 

transmitter

 

 

 

 

TX Rise/Fall Time

 

(UI)

 

(20-80%)

(20-80%)

 

Fall: 80%-20% at

 

 

 

 

 

 

 

transmitter

 

 

 

 

 

 

 

 

tskewTX,

 

ps

 

 

20

 

 

TX Differential Skew

 

 

 

 

 

 

 

TJ at Connector,

 

UI

 

 

0.355

 

 

Data-Data, 5UI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DJ at Connector,

 

UI

 

 

0.175

 

 

Data-Data, 5UI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TJ at Connector,

 

UI

 

 

0.47

 

 

Data-Data, 250UI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DJ at Connector,

 

UI

 

 

0.22

 

 

Data-Data, 250UI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-8