Fujitsu MHV2060BH, MHV2100BH, MHV2080BH, MHV2040BH manual Execution example of Read Multiple command

Models: MHV2100BH MHV2040BH MHV2060BH MHV2080BH

1 274
Download 274 pages 5.42 Kb
Page 151
Image 151

5.3 Host Commands

Host

Reg. HD

PIO Setup

Data

Block

(4 sectors)

 

 

PIO Setup

 

 

 

 

 

 

 

 

Block

 

 

 

Data

 

 

 

(4 sectors)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIO Setup

 

 

 

 

 

 

Partial

 

Data (1sector)

 

 

 

 

Block

 

 

 

 

 

 

 

Device

Figure 5.10 Execution example of READ MULTIPLE command

Error reporting conditions

(1)A specified address exceeds the range where read operations are allowed (ST = 51h, ER = 10h).

(2)The range where read operations are allowed will be exceeded by an address during a read operation (ST = 51h, ER = 10h).

(3)An uncorrectable disk read error occurred (ST = 51h, ER = 40h).

(4)The sync byte indicating the beginning of a sector was not found (ST = 51h, ER = 01h).

(5)The READ MULTIPLE command is disabled (ST = 51h, ER = 04h).

(6)A SATA communication error occurred (ST = 51h, ER = 0Ch).

(7)An error other than the above errors occurred (ST = 51h, ER = 04h).

C141-E224

5-75

Page 151
Image 151
Fujitsu MHV2060BH, MHV2100BH, MHV2080BH, MHV2040BH manual Execution example of Read Multiple command