Installation Conditions

(2) Frame

The MR head bias of the HDD disk enclosure (DE) is zero. The mounting frame is connected to Signal Ground (SG).

IMPORTANT

Use M3 screw for the mounting screw and the screw length should satisfy the specification in Figure 3.3.

The tightening torque must be 0.49N•m (5kgf•cm).

When attaching the HDD to the system frame, do not allow the system frame to touch parts (cover and base) other than parts to which the HDD is attached.

(3) Limitation of mounting

Note) These dimensions are recommended values; if it is not possible to satisfy them, contact us.

 

2.5

 

Side surface

2.5

Bottom surface mounting

2.5

 

mounting

 

 

 

 

 

 

 

 

 

 

DE

 

 

 

 

2.5

 

 

 

 

2

 

PCA

B

A

Frame of system

 

 

Frame of system

cabinet

 

 

 

 

cabinet

 

 

 

 

 

3.0 or less

 

Screw

Screw

3.0 or less

Details of A

Figure 3.3 Mounting frame structure

3-4

C141-E224

Page 48
Image 48
Fujitsu MHV2100BH, MHV2080BH, MHV2040BH, MHV2060BH manual Frame, Limitation of mounting, Pca