Interface
Table 5.26 Features field values and settable modes (2/2)
Features | Drive operation mode | |
Field | ||
| ||
|
| |
X ' AA ' | Enables the read cache function. | |
|
| |
X ' BB ' | Specifies the transfer of | |
commands. (Note) | ||
| ||
|
| |
X ' C2 ' | Disables the Acoustic management function. | |
|
| |
X ' CC ' | Enables the reverting to | |
|
|
Note: Although there is a response to the command, nothing is done.
At
Write cashe function | : Enabled |
Transfer mode | : PIO |
Advanced power |
|
management function | : Enabled |
Acoustic |
|
management function | : State keeping |
Read cashe function | : Enabled |
At
DMA Setup FIS | : Disabled |
: Disabled | |
Software Settings Preservation | : Enabled |
•Error reporting conditions
(1)An undefined code is specified in the FR or SC field (ST = 51h, ER = 04h).
(2)A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block O registers setting contents)
CM | 1 | 1 | 1 | 0 | 1 |
| 1 |
| 1 | 1 |
|
|
|
|
|
|
|
|
|
|
|
DH | x | x | x | x |
|
|
| xx |
| |
|
|
|
|
|
|
|
|
|
| |
CH |
|
|
|
| xx |
|
|
|
| |
CL |
|
|
|
| xx |
|
|
|
| |
SN |
|
|
|
| xx |
|
|
|
| |
SC |
|
|
| xx or *1~3 |
|
|
|
| ||
FR |
|
|
| [See Table 5.6] |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|