The output log file setting has the following modes:

No log output (LOGFILE_MODE=0)

No logs are output.

In the case where a machine frequently has errors and the source of these errors is clear, a large number of similar system log events, none of which require any follow-up, can be generated. In such a case use the "no log" mode to allow the system to run without having to generate the useless log files.

Output startup and error information (LOGFILE_MODE=1)

This outputs logs only when ETERNUSmgr starts up and in the event of an error. Use this mode when space in the log area is restricted.

Output all log information (LOGFILE_MODE=2)

This mode outputs all possible log information from the startup of ETERNUSmgr. Regardless of its eventual success or failure, at least one log is generated by each polling event. It is recom- mended that the system normally be run in this mode.

The output mode is set by modifying the "LOGFILE_MODE" parameter in the setup file ("STX~.INI").

[Default value]

2

[Parameter]

LOGFILE_MODE(0-2)

Caution:

For this parameter, if there is no need for any special setting, it is recommended not to enter any value. This parameter is commented out in the default setup file available after installation.

2.4Modifying the ETERNUSmgr Top Menu System

The ETERNUSmgr Top Menu files are generated automatically when ETERNUSmgr is installed. See the "ETERNUS8000, ETERNUS4000, ETERNUS2000, ETERNUS6000, ETERNUS3000 ETERNUSmgr Install Guide" of each OS for details of installing ETERNUSmgr.

The ETERNUSmgr Top Menu is written as a typical HTML file, and can easily be edited using a text edi- tor.

Perform the following procedures if the Web server URL and alias set during the installation or the Top Menu Settings directory need to be changed.

There is no need to copy the files when using the directory specified during the installation as the Top Menu Settings directory. However, in such case, be sure to make a backup copy of the top menu file ("menu.htm") before editing the original.

Caution:

ETERNUSmgr reads the Top Menu File ("menu.htm") in, and reoutputs it after adding the target device status information to it. Therefore, always stop ETERNUSmgr before making any changes to the base "menu.htm" file.

The "menu.htm" file must be set to be writable.

22

ETERNUSmgr User Guide -Introduction- P2X0-0202-01EN

All Rights Reserved, Copyright © FUJITSU LIMITED 2007

Page 30
Image 30
Fujitsu P2X0-0202-01EN manual Modifying the ETERNUSmgr Top Menu System, Output Log File