Fujitsu P2X0-0202-01EN manual Mail Messages, Alarm Text Fixed File

Models: P2X0-0202-01EN

1 66
Download 66 pages 13.13 Kb
Page 55
Image 55

Chapter 6 Messages

Alarm text date files are automatically deleted when they are older than the limit specified in the setup file. See "Number of Days Alarm Text Date Files are Kept" (page 20) for more information about the setup files.

Alarm Text Fixed File

This is stored in the same directory as the alarm text date files using whatever name is specified in the setup file. See "2.3.4 Alarm Text File Settings" (page 19) for more information about the setup files. When an alarm history file is created, a line formatted as "Year, Month, Day, Hour, Minutes, Seconds, Machine Address, and Machine Status as Recorded in the Alarm History File" is added to the alarm text file.

An example of an alarm text is shown below.

20030101130100 10.20.30.40 No hardware error detected.

20030101130600 10.20.30.40 ControllerEnclosure#00:ALARM

20030101144100 10.20.30.40 No hardware error detected.

See "6.1 Alarm History Messages" (page 45) and "6.3 E-mail Messages" (page 47) for more information on the target device status output to the alarm text files.

6.3E-mail Messages

The administrator can be sent E-mail messages that contain notices of ETERNUSmgr startup and changes in the target device status. These messages indicating changes in the target device status are identical in format to the alarm history messages.

This section explains the E-mail messages sent by ETERNUSmgr and how to respond to them.

ETERNUSmgr VxxLxx - HTTP Polling engine was started.

[Explanation]

The polling engine has started.

[Response]

None

Hardware Status was changed. See below...

[Explanation]

There has been a change in the target device’s status.

[Response]

If the component that caused the problem is displayed after this message, login to

 

the target device and check the status of that component.

 

When "No hardware error detected." is displayed, there is no need to do anything.

 

Detection of offline status is indicated when "No hardware report detected.

 

(Offline)" is displayed. In this case, check for problems with the target device, fail-

 

ures in the communications route, and errors in the setup file.

 

When "An error has occurred in controller enclosure. (BUSY)" is displayed, per-

 

form the following:

 

For ETERNUS3000

 

It has been detected that one of the controllers in the controller enclosure cannot

 

start up. The controller needs to be serviced.

 

For ETERNUS6000

 

Indicates that the target device cannot respond due to device stop status, abnormal-

 

ity of the communication link between the device and SVP, or device boot process-

 

ing. Check that the target device is operating normally, and that there is no problem

 

with the communication link between the device and SVP.

 

For ETERNUS8000, ETERNUS4000, and ETERNUS2000

 

Indicates that the target device cannot respond due to device stop status or device

 

boot processing. Check that the target device is operating normally.

6

P2X0-0202-01EN ETERNUSmgr User Guide -Introduction-

All Rights Reserved, Copyright © FUJITSU LIMITED 2007

47

Page 55
Image 55
Fujitsu P2X0-0202-01EN manual Mail Messages, Alarm Text Fixed File, ETERNUSmgr VxxLxx Http Polling engine was started