Chapter 2 Setup

Busy Target Detection Time

This parameter is used to set the "target device busy" status detection time. Units are seconds.

Depending on what the ETERNUS device is doing, its device status can sometimes temporarily become "busy".

In particular, the device cannot respond while it is booting. Busy status is temporary, it does not mean device abnormality.

When device busy status is detected, ETERNUSmgr inhibits notification with logs or mails of device abnormality for a set period of time.

When the busy status exceeds that definite period of time, ETERNUSmgr notifies of a device abnormality.

[Default value]

1800 (seconds)

[Parameter]

BUSY_TIME (0-65535)

[Example]

BUSY_TIME=1800

Caution:

This setting is not described in the initial setup file. Add if necessary.

This setting needs not be changed.

2.3.2E-mail Notification Settings

2

This section explains how to setup the E-mail notification function. See "6.3 E-mail Messages" (page 47) for the content of E-mail messages provided by this function.

Admin Mail Address

This parameter is used to specify an address to which to send the E-mail generated in the event of change in the target device status. Usually this is the address of the target device administrator.

The E-mail notification function is disabled if this parameter is omitted.

[Parameter]

ADMIN_MAIL (up to 64 characters)

[Example]

ADMIN_MAIL=admin@domain-name.com

To set multiple E-mail addresses, use a comma with no spaces between each address.

ADMIN_MAIL=admin1@domain-name.com,admin2@domain-name.com

Alarm Mailing Interval

This parameter is used to specify the interval for sending generated E-mail in the event of a failure or abnormality in the machine. Units are seconds.

Set the interval in units of seconds within the range of 1 ~ 65535. Set this parameter only if you wish to send E-mail with timing different from the specified Polling Interval. For example, by setting this parame- ter, you can set a short Polling Interval and long Alarm Mailing Interval. This will allow any device errors that may have occurred over this interval to be collected and sent together with other E-mail messages.