2.5 Monitoring Multiple Target Devices

2.5.2.1ETERNUSmgr for Solaris OS and Linux

When adding extra machines, it is easiest to just copy and edit an existing setup file.

Procedure

1Confirm the contents of the installation directory.

Make sure that the necessary files and directories (stxchk, _STXPOLL.INI, STXPOLL_1.INI, stx- poll, stxpolld, www/) have all been installed.

# ls /opt/FJSVgrmgr/

stxchk _STXPOLL.INI STXPOLL_1.INI stxpoll stxpolld www/

2Copy an existing setup file.

File name starts with "STX" and ends with ".INI".

#cp /opt/FJSVgrmgr/STXPOLL_1.INI /opt/FJSVgrmgr/STXPOLL_2.INI

3Confirm the copy results.

#ls /opt/FJSVgrmgr/

stxchk _STXPOLL.INI STXPOLL_1.INI STXPOLL_2.INI stxpoll stxpolld www/

4Edit the copied file. (The STXPOLL_2.INI file is used here.)

Vi editor is used here.

Refer to "2.3 Setting Items" (page 12) for details of how and which parameters should be changed in the new setup file.

#vi /opt/FJSVgrmgr/STXPOLL_2.INI

Caution:

"_STXPOLL.INI" is provided as a model file. If you copy this file to make a new setup file, be sure to keep the original file as is.

2.5.2.2ETERNUSmgr for Windows®

When adding extra machines, it is easiest to just copy and edit an existing setup file.

Procedure

1Confirm the contents of the installation directory using Explorer, etc.

Make sure the following files and folder have been installed in the installation directory: _stxpoll.ini, STXPOLL.exe, STXPOLL_1.INI, stxpolld.exe, stxsmail.exe, and \www (\www is a folder).

2Copy an existing setup file.

Example: STXPOLL_1.INI

3Change the name of the copied file.

Setup file names must start with "STX" and end with ".INI". Example: STXPOLL_2.INI

28

4Edit the copied file. (The STXPOLL_2.INI file is used here.)

Use a text editor such as Note Pad to edit the copied files.

Refer to "2.3 Setting Items" (page 12) for details of how and which parameters should be changed in the new setup file.

ETERNUSmgr User Guide -Introduction- P2X0-0202-01EN

All Rights Reserved, Copyright © FUJITSU LIMITED 2007

Page 36
Image 36