Chapter 5 Cautions

4Delete the setup files from the ETERNUSmgr directory created by the installation process.

5Move the GRmgr V10L30 (or later) setup files from their temporary location (step 1) into the ETERNUSmgr directory.

Note that ETERNUSmgr must be installed in the same directory as was used by the previous version of GRmgr (V10L30, V10L40, V10L50, V10L60). Similarly, the new www files must be installed in the old www directory, and if the old top menu file ("menu.htm") has been edited, it should be backed up and used to replace the new version.

- When using a GRmgr V10L30 setup file, append the following Detect Offline Targets parame- ter description to the setup file if you wish to use the offline detection function (available from GRmgr V10L40 onward).

# Detect Offline status

DETECT_OFFLINE = TRUE

-This flag does not need to be added to the GRmgr V10L30 setup file if the offline detection function (available from GRmgr V10L40 onward) is not going to be used.

See "Detect Offline Targets" (page 14) for details of the Detect Offline Targets parameter.

Setup files

Always ensure that the ETERNUSmgr setup file’s TARGET_FLAG parameter is correct for the monitored device type. ETERNUSmgr will be unable to monitor the target device if this setting is wrong. Note that even if the TARGET_TYPE and the TARGET_FLAG set- tings are different, ETERNUSmgr operations are not affected.

Any character string may be set in TARGET_TYPE, however it is recommended that the correct device type ("ETERNUS8000", "ETERNUS4000", "ETERNUS2000", "ETERNUS6000", "ETERNUS3000", "GR710", "GR720", "GR730", "GR740", "GR820", or "GR840") be set. The character string in TARGET_TYPE is used when the administrator is notified by E-mail, and in the alarm history files.

Edit only the parameters in the ETERNUSmgr setup file which are explained in this docu- ment. Do not delete comments or blank lines from the default setup files provided, and do not add anything other than allowed parameters. Failure to follow these requirements may result in problems, and prevent future upgrades of ETERNUSmgr. See "Chapter 2 Setup" (page 9) for details.

Install/Uninstall

See the "ETERNUS8000, ETERNUS4000, ETERNUS2000, ETERNUS6000, ETERNUS3000 ETERNUSmgr Install Guide" for details of installing and uninstalling ETERNUSmgr.

5

P2X0-0202-01EN ETERNUSmgr User Guide -Introduction-

All Rights Reserved, Copyright © FUJITSU LIMITED 2007

43