Fujitsu P2X0-0202-01EN manual Alarm Text Files, Alarm Text Date Files, StxgrYYYYMMDD.log

Models: P2X0-0202-01EN

1 66
Download 66 pages 13.13 Kb
Page 54
Image 54

6.2 Alarm Text Files

ETERNUS3000 Hardware Status List

Date:1/1/2003

ETERNUS3000 Address:10.20.30.40

ControllerEnclosure#0001:ALARM

ControllerEnclosure#0002:BTU-CAUTION

ControllerEnclosure#0003:ALARM&BTU-CAUTION

DriveEnclosure#0003:ALARM

ETERNUSmgr(stxpoll) V20L20

Header

(title, date, address of the target device)

Alarm List

Footer

(ETERNUSmgr Version)

The "alarm history messages" shown above indicate the status results obtained from the target device. The following message is output when all components of the target device are normal.

"No hardware error detected."

If target device monitoring does not work properly (due to LAN drop-out, failure on the network path, or incorrect target address setting, etc.), and the Detect Offline Targets parameter has been set, the following message will be output.

"No hardware report detected. (Offline)"

See "6.3 E-mail Messages" (page 47), "Hardware Status was changed. See below ..." for details of the mes- sages displayed in the alarm history file.

Note that "Hardware Status was changed. See below ..." is not an actual alarm history message.

6.2Alarm Text Files

This section explains the alarm text files that are generated by ETERNUSmgr.

Alarm text files are a compilation of the alarm history messages for a single day in a text format. See "6.1 Alarm History Messages" (page 45) for more information on the alarm history messages.

Alarm text files are categorized into the following types:

Alarm Text Date Files

Contains the individual alarm history messages that record the ongoing status of the tar- get device, collected on a day-by-day basis.

Alarm Text Fixed File

Contains the same alarm history messages as the latest alarm text date file, saved under a settable name.

Alarm Text Date Files

The alarm text date file is saved in the directory specified in the setup file using the following file naming convention. See "2.3.4 Alarm Text File Settings" (page 19) for more information about the setup files.

stxgrYYYYMMDD.log

YYYY : Year

MM: Month

DD : Day

46

For example, "stxgr20030101.log" indicates an alarm text date file that was created on January 1, 2003. Alarm text date files are created/updated when an alarm history file is created. Alarm text date files are cre- ated/updated when an alarm history file is created.

ETERNUSmgr User Guide -Introduction- P2X0-0202-01EN