XG Series User's Guide Chapter 5 Command Reference
Port Information Settings
106
5.1.1.16 ether downrelay port
Function Set the linked port list information about the Linkdown Relay function.
Available Model XG0224 / XG0448 / XG2600
Syntax ether <number> downrelay port <portlist>
Options
<number>
ether port number
Set a port number to use with a decimal value.
When setting multiple port numbers, separate them with commas (,).
When setting sequential numbers, separate them with hyphens (-). (Example: "1-8")
<portlist>
Relay port list
Set a list of the Ethernet ports that go offline (linkdown) together with the linked
Ethernet port that has been set by this definition when the linkdown of the linked
Ethernet port occurs.
When setting multiple port numbers, separate them with commas (,).
When setting sequential numbers, separate them with hyphens (-). (Example: "1-8")
Use Mode Configuration mode (admin class)
Explanation Set a list of the Ethernet ports that go offline (linkdown) together with the linked Ethernet
port that has been set by this definition when the linkdown of the Ethernet port occurs.
If the linkdown relay operation occurs, the linked port goes offline, and the log is output to
the SYSLOG.
Caution
If ports are offline, release them by the "online" command with port releasing.
The definition is applied normally even if the set port is included on the relay operation
port list. However, if the set only port is included on the list, no relay operation occurs
but only the set port goes offline.
When the Ethernet port type is a linkaggregation port, and linked port list information
for the Linkdown Relay function of the linkaggregation is set, the Linkdown Relay
function of the linkaggregation becomes enable and this definition is ignored.
The linked port does not go offline at the Linkdown operation during the dynamic
definition change on the Ethernet port where this command is set.
Default The linkdown relay function is not executed, assuming that port list information has not
been set.