XG Series User's Guide Chapter 5 Command Reference
Device Information Settings
302
5.15.8.4 telnetinfo
Function Set the TELNET connection service.
Available Model XG0224 / XG0448 / XG2600
Syntax telnetinfo autologout <time>
Options
<time>
Automatic disconnection time
Specify a time period (from 0 to 86400 seconds (one day)) for the user to be
automatically disconnected when no command input/output processing has been
performed by the client while connected through telnet.
The unit shall be d (day), h (hour), m (minute), or s (second).
Use Mode Configuration mode (admin class)
Explanation Set a time period to disconnect the TELNET connection when no data is input and
output.
Default It is assumed that TELNET connection input/output is not monitored.
5.15.8.5 mflag
Function Set the CE maintenance login.
Available Model XG0224 / XG0448 / XG2600
Syntax mflag <mode>
Options
<mode>
on
Specify it when enabling login using a CE-dedicated password.
off
Specify it when disabling login using a CE-dedicated password.
Use Mode Configuration mode (admin class)
Explanation Set whether or not to permit CE maintenance login.
Default It is assumed that login with a CE-dedicated password is rejected.
telnetinfo autologout 0s
mflag off