XG Series User's Guide Chapter 5 Command Reference
Ethernet Counter, Log, Statistics, and Status Display and Clear Operation
Commands
387
5.20.1.2 show ether brief
Function Display the information about Ethernet physical ports briefly.
Available Model XG0224 / XG0448 / XG2600
Syntax show ether brief
Options
N/A
Display all information.
Use Mode Operation mode (user class/admin class)
Configuration mode (admin class)
Explanation Display the Ethernet port information briefly.
Execution Example
1) Port number
2) Port state
up : Indicates that the port is in the linkup state.
down : Indicates that the port is in the linkdown state.
standby : Indicates that the port is in the standby state. (backup port only)
"*standby" is displayed when the port is not established (not
switched) as a standby port in the linkup state.
offline : Indicates that the port is in the offline state.
disable : Indicates that the port is not used based on the definition.
3) Port type
normal : Indicates that the port is used as a normal port.
mirror : Indicates that the port is used as a target port for mirroring.
# show ether brief
port status type media mdi speed duplex flow
----- -------- ------------------ ------ ----- ------ ------- -----
(1) (2) (3) (4) (5) (6) (7) (8)
1 up normal metal MDIX 1000M full TxRx
2 up normal metal MDI 1000M full Rx
3 up linkaggregation1 metal - 1000M full TxRx
4 up linkaggregation1 metal - 1000M full TxRx
5 up linkaggregation1 metal - 1000M full TxRx
6 up linkaggregation1 metal - 1000M full TxRx
7 offline normal - - - - -
8 up backup1 metal MDIX 1000M full -
9 standby backup1 metal MDIX 1000M full -
10 down normal - - - - -
11 down normal - - - - -
12 up linkaggregation4 metal MDIX 1000M full Tx
13 up linkaggregation4 metal MDIX 1000M full Tx
14 disable normal - - - - -
15 disable normal - - - - -
16 down mirror - - - - -
17 up normal metal MDIX 1000M full Rx
18 up normal metal MDIX 1000M full Rx
19 up normal metal MDIX 1000M full Rx
20 up normal metal MDIX 1000M full Rx
21 up normal metal - 1000M full Rx
22 up normal metal - 1000M full Rx
23 up normal metal - 1000M full Rx
24 up normal metal - 1000M full Rx
25 up normal metal - 1000M full Rx
26 up normal metal - 1000M full Rx
#