XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
551
3) restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on : The power has been turned on.
reset : The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4) machine_state
State of the device
RUNNING: The device is active.
5) power0_state
State of the power unit.
NORMAL : The power unit works normally.
NO_PRESENT : The power unit is not installed.
FAIL : The power unit has been turned off.
UNKNOWN : The power unit is invalid state.
6) fan0_state
State of the fan 0.
fan1_state
State of the fan 1.
fan2_state
State of the fan 2.
NORMAL : The fan works normally.
ABNORMAL : The fan has been abnormal.
UNKNOWN : The fan is invalid state.
7) inspiration_state
State of environment temperature monitor.
phy_state
State of temperature monitor around PHY.
slot1_state
State of Expansion Card temperature monitor (SLOT1).
slot2_state
State of Expansion Card temperature monitor (SLOT2).
NORMAL : The temperature is normal.
HIGHWARNING : The device changes to a high temperature state.
HIGHALARM : Thermal alarm occurs in the device.
UNKNOWN : There are three following states.
The Expantion Card without Thermal Sensor is installed. (CX4)
The Invalid Expantion Card is installed.
The Expantion Card is not installed.
8) inspiration_temp
Environment temperature.
phy_temp
temperature around PHY.
slot1_temp
temperature around Expansion Card (SLOT1).
At the time of three following states, "--" is displayed.
The Expantion Card without Thermal Sensor is installed. (CX4)
The Invalid Expantion Card is installed.
The Expantion Card is not installed.