Installing the heat sink

Processors

Installing a second processor

Installing the heat sink

Figure 10: Installing the heat sink 2Installing the ventilation duct

Manual backgroundManual background 1

Figure 10: Installing the heat sink

ÊFit the heat sink on the processor such that the side labeled “FRONT” (see arrow (1) in figure above) is facing the front of the server.

ÊAttach the heat sink with four screws. Tighten the screws in diagonally opposite sequence (2).

VCAUTION!

Never install a processor without a heat sink! The processor is likely to overheat, which may cause damage to the processor and the system board.

Installing the ventilation duct

ÊReinstall the ventilation duct (see page 20).

ÊClose the server, plug in the power plugs, and switch on the server as described in the chapter “Completion” on page 45.