www.gateway.com | Replacing the RPS power distribution module |
Replacing the RPS power distribution module
To replace the RPS power distribution module:
1Follow the instructions in “Preventing static electricity discharge” on page 30. Make sure that you turn off the server, then unplug the power cord(s) and all other cables connected to the server.
2Follow the instructions in “Opening the server case” on page 31.
3Remove the power supply modules by following the instructions in “Replacing a power supply module” on page 52.
4Disconnect the main power, CPU power, backplane power, I2C power, and midplane power cables. See “System board” on page 6 for the location of the connectors on the system board.
5Push down the release bar (1). When the RPS power distribution module lifts (automatically), pull it away from the power supply cage (2) and remove it from the chassis.
Important
Make sure that the RPS power distribution module is connected to the power supply connector(s) on the power supply(ies).
6Align the new RPS power distribution module with the power supply cage (1), then push it down (2) onto the release bar. Make sure that the connectors on the back of the RPS power distribution module fit into the connectors on the power supply(ies).
7Reconnect the power cables. See “System board” on page 6 for the location of the connectors on the system board.
8Reinstall the power supply modules by following the instructions in “Replacing a power supply module” on page 52.
9 Follow the instructions in “Closing the server case” on page 32.
53