Note

The sensor number can be changed during program mode by pressing the num- bered keys after pressing the sensor button. Sensors can be numbered 01 to 24. Be sure to enter 0 before the number for sensor numbers 1 to 9. The sensor number cannot be changed after it has been programmed.

To Add or Replace a Sensor using the Programming Buttons under the Panel Cover

1.Open the front cover.

2.Enter the Utility 1 or Utility 2 Access Code.

3.Press the Add button from the Start menu. The panel announces “Select from Main Menu.”

4.Press Sensor from the Main Menu.

The panel will announce “Press button on sensor X.” X is the next available sensor number. If 24 sensors are already programmed into the panel the panel says “Invalid. Twenty-four sen- sors already programmed.”

5.Trip the sensor.

See Table 8 for descriptions of how to trip each type of sensor. The panel will announce “Press status to accept sensor.” DO NOT press Status at this time. Move on to Step 6.

6.If necessary, change the Sensor name by pressing the Option # button. See Table 8 for Sensor Type Options.

7.Press the Done button to program the sensor.

The system will announce the sensor name, type and number.

Table 8: Programming Sensors

Sensor Type

To Trip

Sensor Type Options

 

 

 

 

 

 

Personal Help Button

Press the help button on the sensor.

Emergency Sensor Type Not Supervised

 

 

Emergency Sensor type Supervised

 

 

 

Pendant Help Button

Press the help button on the sensor.

Emergency Sensor Type Not Supervised

 

 

Emergency Sensor type Supervised

 

 

 

Door/Window Sensor

With the Door/Window Sensor cover

Activity Sensor type Supervised

 

removed, press the Program button on

Activity Sensor type Not Supervised

 

the top of the sensor.

 

 

 

 

Freeze Sensor

With the Freeze Sensor cover

Freeze Sensor type Supervised

 

removed, press the Program button on

 

 

the top of the sensor.

 

 

 

 

Water Sensor

With the Water Sensor cover

Water Sensor type Supervised

 

removed, press the Program button on

 

 

the top of the sensor.

 

 

 

 

Smoke Alarm

Remove the base of the Smoke Alarm

Smoke Sensor type Supervised

 

 

 

Carbon Monoxide (CO)

Plug in the CO Alarm. Within 60 sec-

Carbon Monoxide Sensor type Supervised

Alarm

onds of plugging in, press and hold the

 

 

Test/Reset button until you hear 6

 

 

beeps.

 

 

 

 

Motion Sensor

Remove the sensor from its mounting

Activity Sensor type Supervised

 

plate.

Activity Sensor type Not Supervised

 

 

 

Repeater

With the Repeater cover removed,

Repeater module type Supervised

 

press the tamper switch spring on the

 

 

circuit board.

 

 

 

 

Adding/Replacing Sensors

22

Page 27
Image 27
GE 60-883-95R installation instructions Sensor Type To Trip Sensor Type Options