GE 60-883-95R Special Installation Requirements, ETL Listed Installations

Models: 60-883-95R

1 34
Download 34 pages 3.55 Kb
Page 6
Image 6
Special Installation Requirements

About this Manual

This manual provides advanced information for planning, installing programming, operating, and testing a CareGard system. Complete operation instructions are available in the CareGard User Instructions (Part No. 466-1936).

Special Installation Requirements

This system is designed to be used as an emergency notification system. Some installations may require configurations dictated by city or state codes, or insurance.

ETL Listed Installations

The following are requirements for ETL listed installations:

Basic System

Control Panel

Backup Battery

Standard Class II 9 VAC 700 mA Power Transformer

Wrist Panic

Digital Alarm Communicator System (UL 1635)

These options are required only if the system is set up for central station reporting.

Option 3: Primary Phone Number programmed

Option 10: Phone Mod 1 set to 0 or 1

Option 14: Auto Phone Test set to 001

Option 15: RF Timeout set to 4 hours

Option 17: AC Power Failure Report set to 15 minutes

Option 18: CPU Low Battery Report set to on

Option 27: RF Jam Detect set to on

Home Health Care Signaling Equipment (UL 1637)

Basic System

Panic Sensor

Central Station Reporting

The panel has been tested with the following central station receivers using SIA and Contact ID reporting formats:

Radionics D6600 Central Station Receiver

Sur-Gard Central Station Receiver with models SG-DRL2A and SG-CPM2

1

About this Manual

Page 6
Image 6
GE 60-883-95R Special Installation Requirements, ETL Listed Installations, Central Station Reporting