Option 18: CPU Low Battery Report |
|
| Range = On/Off (Default = On) | |||
Determines whether the panel sends a low CPU battery report to the central | ¾ To Add or Delete CPU Low Battery | |||||
station when the panel backup battery voltage drops below 5.4 volts (on), or |
| Report: | ||||
not (off). |
| 1. | Press Add or Delete. | |||
A CPU Low Battery Report is also sent at the time specified by Option 32: | 2. | Press Option #. | ||||
Supervisory Time. When the backup battery is restored a system battery | 3. | Press 1, then 8. | ||||
restoral report will be sent to the central station. |
| |||||
| 4. | Press Done. | ||||
Note |
| |||||
|
|
|
| |||
CPU Low Battery Report must be turned on for ETL (UL 1635) listed systems. |
|
|
| |||
|
|
|
|
|
| |
Option 19: Fail to Communicate |
|
| Range = On/Off (Default = On) | |||
|
|
|
|
| ||
Determines whether the panel sounds trouble beeps if it is unable to success- | ¾ To Add or Delete Fail to Communicate: | |||||
fully send a report to a central station or pager (on), or not (off). |
| 1. | Press Add or Delete. | |||
Note |
| 2. | Press Option #. | |||
The panel will try each programmed phone number 8 times before announcing a | 3. | Press 1, then 8. | ||||
system phone communication failure. |
| |||||
If Option 11 is set to 6 or 7 after 3 failed attempts with the phone 1 number a | 4. | Press Done. | ||||
phone communication failure occurs |
| |||||
|
|
|
| |||
|
|
|
|
|
| |
Option 20: Ring/Hang/Ring |
|
| Range = On/Off (Default = 1) | |||
|
|
|
|
| ||
Determines when the panel answers a remote phone access call. Depending | ¾ To program Ring/Hang/Ring: | |||||
on whether an answering machine exists at the panel location, | 1. | Press Add. | ||||
to the panel can be achieved with a series of phone calls or just one. Table 5 | 2. | Press Option #. | ||||
shows the available settings. |
| |||||
¾ For | 3. | Press 2, then 0. | ||||
4. | Enter a Ring/Hang/Ring setting using the | |||||
must perform the following steps: |
| |||||
1. Call the panel location. |
|
| numbered buttons. | |||
| 5. | Press Done. | ||||
2. Let the Phone ring once, then hang up. |
| |||||
|
|
|
| |||
3. Wait at least 10 seconds but not more than 40, then call the panel location |
|
|
| |||
again. The panel should answer on the first ring. |
|
|
|
| ||
• If set to 1, perform steps |
|
|
|
| ||
• If set to 2, perform steps |
|
|
|
| ||
• If set to 3, perform steps |
|
|
|
| ||
See “Phone Communication” in the Testing the System section of this man- |
|
|
| |||
ual for the commands used for remote phone control. |
|
|
|
| ||
Note |
|
|
|
| ||
For |
|
|
| |||
calls the panel location once and listens for 10 rings. The panel should answer |
|
|
| |||
after the tenth ring. |
|
|
|
| ||
|
|
|
| |||
| Table 5: Ring/Hang/Ring Settings | |||||
|
|
|
| |||
| Setting | Control Panel answers after: |
| |||
|
|
|
| |||
|
|
|
| |||
| 1 | ring/hang/ring or 10 rings |
| |||
|
|
|
| |||
| 2 | ring/hang/ring/hang/ring or 10 rings |
| |||
|
|
|
| |||
| 3 | ring/hang/ring/hang/ring/hang/ring or 10 |
| |||
|
| rings |
|
|
| |
|
|
|
|
|
| |
| 4 | 10 rings |
|
|
| |
|
|
|
| |||
| Off | Disabled - no remote |
| |||
|
|
|
|
|
|
13 | Programming Options |